Modular Building Technical Specs & Information
OUR BUILT TO CODE COMMITMENT
Structural Performance
Starrco Modular Offices for sale are designed to comply with structural requirements of the International Building Code, with regard to load-bearing design, roof deflection and lateral load resistance. A Starrco prefabricated office can also be designed to meet earthquake zone requirements.
Fire Protection
Starrco’s DL wall systems have gypsum board panels and commercial grade 20ga. steel doors with 18ga. steel frames. All components of these wall systems are non-combustible. The sandwich panels have been tested by Guardian Fire Testing Laboratories in accordance to ASTM-E-2768. These modular wall panels were found to be class A fire resistant with a flame spread of less than 5 and a smoke density of less than 10. Copies of the test results are available upon request.
Electrical
AII electrical components are UL listed. The electrical handy box meets NEC (National Electric Code) requirements
Accessibility
ADA (Americans with Disabilities Act) compliant locksets and door closers are available upon request. Starrco’s standard doors meet the width requirements for the ADA.
State Sealed Drawings